BWO tubes for 33-170
GHz in four bands
- Full
wave guide operation
- Smooth
power/frequency dependence
- High
output power, 50 mW on 100 GHz typical
- Supplied
packaged in a magnet
- Grid
for power regulation
- Delivery
from stock
|
Power/Frequency
dependencies for tubes we offer from stock
BWO Tubes Description
Main
advantages of BWO tubes series BWO-xx are very smooth dependence
of output power versus frequency and high output power. Unique
technology applied for producing of BWO tubes allows to obtain
oscillations within a full waveguide frequency band without
deep points. We supply each BWO tube with a personal calibration
for output power versus frequency and frequency versus high
voltage dependencies. Operation frequency of BWO tube depends on high
voltage applied on a deceleration system of the tube - anode
voltage. Anode current can be controlled by means of a control
electrode - the grid that allows to control the output millimeter
wave power. The BWO tube allows to change frequency and power
independently and very fast - few microseconds for full band
frequency sweep and about 10 ns for on/off power modulation.
Specification
|
Model
|
BWO-Q
(BWO6)
|
BWO-U
|
BWO-V
(BWO4)
|
BWO-E
|
BWO-W
(BWO3)
|
BWO-F
|
BWO-D
(BWO2)
|
|
..Operating
range, GHz
|
33-50
|
40-60
|
50-75
|
60-90
|
75-110
|
90-140
|
110-170
|
|
..Output
power, min, mW
|
15-40
|
30-50
|
12-30
|
15-40
|
6-30
|
10-30
|
6-20
|
|
..Power
difference in the range, max, dB
|
3-5
|
3-6
|
3-5
|
3-6
|
3-6
|
3-6
|
3-6
|
|
..Anode
voltage, V
|
350-1200
|
700-1700
|
350-1200
|
700-1700
|
400-1500
|
800-2500
|
400-2500
|
|
..Cathode
current, mA
|
20-25
|
20-25
|
20-25
|
20-25
|
20-25
|
20-25
|
20-25
|
|
..MTBF,
h
|
2000
|
1500
|
2000
|
1500
|
1000
|
1000
|
1000
|
The
typical power/frequency and frequency versus high voltage
applied to deceleration system dependencies are shown on the
plots below for BWO-W model.
The
dependencies of output power versus anode current are presented
for 7 tubes on left plot below. The power measured on 100 GHz
frequency. On the right plot the dependencies of anode current
versus heating voltage are shown.

U anode as mentioned in the table,
U control=+50... +200 VDC, U heating=+1.0...+1.2 VDC
|